Open the announcement
NEW · The renewed Zenit Programs website is live – discover the new interface and services!

WeldExp calculations

Typical Heat Inputs

Overview of typical heat-input data related to welding procedure parameters.

Specific heat input, based on voltage, current, welding speed and process efficiency, is one of the procedure inputs used in preheat calculations. The WeldExp data view makes the recorded typical heat-input data searchable.

Table Viewer

Typical heat-input data

SizeWelding processUheg_minUheg_maxIheg_minIheg_maxvh_minvh_maxvheg_minvheg_maxQ_minQ_max
1.14 (7/128)MAG25.0034.00200.00350.006.0016.000.905.71
1.0 (3/64)MAG27.0032.00180.00300.006.0018.600.754.61
0.9 (1/28)MAG-FC24.0033.00100.00280.008.0018.000.383.33
0.8 (1/32)MAG24.0028.00150.00280.005.0018.000.584.52
0.6 (2/85)MAG15.0020.0030.00100.005.5013.000.101.05
3.0 (1/8)SAW30.0040.00400.00800.002.506.007.2046.08
2.4 (3/32)MAG32.0045.00420.00600.002.509.004.3031.10
2.0 (5/64)MAG32.0044.00300.00650.004.0015.001.8420.59
1.6 (1/16)MAG-FC32.0040.00500.00660.0011.6819.102.416.51
1.4 (1/18)MAG26.0038.00180.00420.004.5015.000.9010.21

Number of results: 20